Impedance Analyzer 6632 Series
6632-1/3/5/10/20/30/50

Impedance Analyzer 6632 Series|6632-1/3/5/10/20/30/50
Features
  • Frequency range: DC, 10Hz to 1/3/5/10/20/30MHz/50MHz
  • Basic accuracy up to ±0.08% (typical ±0.05% )
  • Automatic Level Control (ALC)
  • Output impedance 25Ω/100Ω, switchable
  • Support meter mode and list mode, sweep mode
  • Built-in DC Bias voltage ±12V
  • Ultra-high measuring speed < 3ms
  • Open circuit/short circuit/load correction function
  • Comparator function
  • BIN classification function
  • Built-in the Permeability-μr
  • Built-in the Dielectric constant-εr

MICROTEST 6632 Impedance Analyzer offers a wide frequency range of 10Hz to 50MHz for measuring the impedance characteristics of components and materials. The measured parameters include |Z| (impedance), |Y| (admittance), θ (phase angle), X (reactance), R (series/parallel resistance), G (conductance), B (Susceptance), L (inductance), D (dissipation factor), Q (quality factor), DCR (DC resistance), C (capacitance), ESR (equivalent series resistance), ε (relative permittivity), and μr (relative permeability). It supports both Meter mode and Sweep Analysis mode, allowing measurement results to be displayed in numeric or graphical formats. It supports LAN/USB Host/USB Device/GPIB/RS-232 communication interfaces, making it compatible with automation equipment or human-machine interfaces (PLC).

Specifications

Selection

6632 Series
Model 6632-1 6632-3 6632-5 6632-10 6632-20 6632-30 6632-50
Frequency

10Hz-

1MHz

10Hz-

3MHz

10Hz-

5MHz

10Hz-

10MHz

10Hz-

20MHz

10Hz-

30MHz

10Hz-

50MHz

SPEC

Model 6632
Frequency Range 10Hz-50MHz
Frequency Setting Continuity
Frequency Resolution 100mHz, 6-bit Frequency Input
Frequency Output Accuracy ±0.01%
Basic Accuracy ±0.08% (typical ±0.05%)
AC Drive Level Test Signal Voltage Level

                 10mV - 2Vrms(100Ω)

                 10mV - 1Vrms(25Ω)

Voltage Minimum Resolution 1mV
Accuracy

         ALC ON:6% * Voltage ±2mV

         ALC OFF:10% * Voltage ±2mV

Test Signal Current Level 200µA - 20mArms
Current Minimum Resolution 10µA
Accuracy

         ALC ON:6% * Current ± 20µA

         ALC OFF:10% * Current ± 20µA

DC Drive Level 1V (fixed)
Output Impedance 25Ω/100Ω (switchable)
DC Bias Voltage

Built-in ±12V

(100Hz-50MHz)

External Voltage Bias

(±12V/±40V/±600V/±2000V)

DC Bias Current

Option DC Bias Current Source

(20A/60A/120A/320A)

External Voltage Bias

(100mA)

Measurement Mode Meter mode, list mode, sweep mode, and optional equivalent circuit analysis function (S model)
Measurement Parameters

|Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C、 ESR、εr 、μr

Test Time (Fastest) < 3mS 

Measurement Parameters

Parameters Range
|Z| 0.000 mΩ to 9999.99 MΩ
R, X ± 0.000 mΩ to 9999.99 MΩ
|Y| 0.00000 μS to 999.999 kS
G, B ± 0.00000 μS to 999.999 kS
θRAD ± 0.00000 to 3.14159
θDEG ± 0.000° to 180.000°
Cs, Cp ± 0.00000 pF to 9999.99 F
Ls, Lp ± 0.00 nH to 9999.99 kH
D 0.00000 to 9999.99
Q 0.00 to 9999.99
Δ ± 0.00% to 9999.99%
Rdc 0.00 mΩ to 99.9999 MΩ
εr' εr'' 0 to 100000
μr' μr'' 0 to 100000

System

  Measurement Circuit Series/Parallel
  Correction Open Circuit/Short Circuit/Load correction
Cable Compensation 0 / 0.5 / 1 /2 (m)
  BIN ABS、ΔABS、Δ%、OFF
  Comparator 9
  List Mode 50 groups of Multi-steps setting (Each group contains up to 15 steps)
Bulit-in Storge 100 sets LCR setting documents, 50 groups of list mode setting
USB Host Storge LCR setting documents, list mode setting document, BMP graphics, Sweep screen and test result data
  Trigger Test Auto, manual, RS-232, GPIB, Handler
  Power Supply Voltage:90-264Vac
Frequency:47-63Hz
  Power consumption 30VA
  Environment Temperature:10℃-40℃
Humidity:20-90%RH
  Dimension 336x147x340 mm (W*H*D)
  Weight 3.95 Kg
  Interface RS-232、Handler、LAN、USB Host、USB Device
Display Color Screen, 7" TFT (800*480)