モーターステータ試験システム
MT-6917 (17 Channel)

モーターステータ試験システム|MT-6917 (17 Channel)
Features

 

 

  • ワンストップでの統合型ステータ高電圧/低電圧電気試験システムです。
  • 17セットの試験チャネルを提供します。
  • AC耐電圧は5000Vです。
  • DC耐電圧は6000Vです。
  • アーク機能で検出できます。
  • 四線式DCR測定(温度補償)を提供します。
  • インパルス巻線短絡試験

Specifications

Selection

MICROTEST stator testing solution can be tailored into a complete testing system based on different requirements. Firstly, you can evaluate whether to opt for a rack-mounted or desktop configuration, as well as whether to incorporate PC connectivity.

 

System Benchtop Rack

 

 

 

Evaluate whether to include PC connectivity software.
Function Operate directly on the instrument  PC Link
Production Traceability Management - Implementing Bar Code/Label Printer/Laser Engraver /
Store test file sets

100 sets (existing instruments)

Unlimited (according to PC memory)

Sharing test files between devices

Unable to share, recreate the file

Share through PC software

Accessing test data /

Transfer test data to the PC via the RS-232 interface

Uploading test data to a cloud database /
User Permission Management" or "User Access Control

/

 

Supports permission management, configuration through Engineering Mode

CPK Report

/

 

 

Customized CPK Report According to Customer Requirements /

 

SPEC 

 Model  MT-6917  MT-6913  MT-6913L  MT-6910
 Test Channel  17 13  13
 DCR Range  0.1mΩ-100kΩ  0.1mΩ-100kΩ  0.1mΩ-150Ω  0.1mΩ-100kΩ
DCR Accuracy

Low Resistance

0.1mΩ-1Ω

±(0.2%±1mΩ)

Low Resistance

0.1mΩ-1Ω

±(0.2%±1mΩ)

Low Resistance

0.1mΩ-200mΩ

±(0.1%±0.5mΩ)

Low Resistance

0.1mΩ-1Ω

±(0.2%±1mΩ)

High Resistance

1Ω-100KΩ

±0.1%

 

 

High Resistance

1Ω-100KΩ

±0.1%

 

 

High Resistance

200mΩ-1Ω

±(0.1%±2mΩ

1Ω-150Ω

±0.5%

High Resistance

1Ω-100KΩ

±0.1%

 

 

 

SPEC

Model MT-6917
DC Resistance Test (6917)
DCR Range 0.1mΩ-100kΩ
Measuring Mode 4-Wire
Safety Hi pot Test (7605)
AC Output Voltage 100V-5000V
AC Leakage Current 0.001mA-10mA
AC Arcing Detection Detect gears from 0-9
DC Output Voltage 100V-6000V
DC Leakage Current 0.001mA-5mA
DC Arcing Detection Detect gears from 0-9
IR Output Voltage 100V-1000V
Insulation Resistance 1-9999MΩ
Measuring Time 0.1-99.9s Continuously adjustable
Voltage Accuracy ±(3% of setting+5V)
Impulse Winding Test (6917)
Impulse Voltage (programmable) 200V-3000V
Impulse Voltage Accuracy ±2%
Total area comparison

When layer short happened, the loss of power on coil increase, the resonance damping coefficient increase, resonance amplitude decrease, the total area decrease. These are the basic parameters we check layer short.

By calculating and comparing the deference of area between golden sample and DUT.
Show by percentage
Analysis the power loss by this data.

Differential area comparison

Add up the difference between normal wave and DUT wave call “ Area differential”.
When layer short happened, the inductance reduce(similar the transformer). The wave phase change and the area differential also change. This will show “fail” on the instrument.
However, the parameter might cause deviation because of the deviation of inductance, resonance phase shift. (Silicon steel product such as motor and traditional transformer is not suitable)

By calculating and comparing the deference of area between golden sample and DUT. To determine the degree of waveform overlap.
Compare the inductance by this.

Wave comparison Set a acceptable wave range, if the DUT’s wave is in this range shows “pass” otherwise, “fail”
This parameter can judge both amplitude and phase of resonance wave. This can increase the detection capability of layer short.
Corona comparison In pulse test, the insulation defect will cause discharge and create corona. This function is able to count the times that corona happened base on the degree of deviation.
Detect the discharge phenomenon on the coil.
Flat comparison If the layer short happened, the waveform will tremble. Therefore, the instrument will quantize and compared it.
Inductance Measurement (Option LCR Meter 6365)
Inductance Ranges 0.1nH - 99.999KH
Test Frequency 10Hz-200kHz
Frequency Output Accuracy ±0.01%
Frequency Resolution 5 Digits
AC Drive Level 10mV to 2Vrms (1m Vrms resolution)
Basic Accuracy ±0.1%
Three-phase Inductance Balance Test

Comparison Mode

  • The absolute value of the difference between the two sets of coil inductance

 

  • The ratio of the absolute value of the difference between the two sets of coil inductance to the standard value

 

  • The ratio of the absolute value of the difference between the inductance of the two sets
    of coils and the average value of the measured resistance of the three sets of coils

 

SYSTEM

Test fixture According to the test requirements
Indicator Pass/Fail Screen Diaplay/Sound
Built-in Storage Storage of 100 rewritable data sets
Operation Manual, RS-232
Power Supply Voltage 90-132Vac or 198-264Vac
Frequency 50/60Hz
Power consumption 300VA
Environment Temperature 10℃-40℃
Humidity 20-90%RH
Display 6917 5.7" dot-matrix display (320*240)
7605 4.3" TFT LCD (480*272)
6365 7.0" TFT (800*480)

Dimension

(W*H*D)

6917 435x190x522mm
7605 435x145x522mm
6365 435x145x522mm
Weight 6917 15 Kg
7605 14 Kg
6365 3 Kg
Interface RS-232