The FPC four-wire high breakover voltage testing machine 9331 is the ideal solution for breakover impedance of few points and high voltage insulation. This is especially the case with flexible circuit board FPCs vulnerable to expanding, contracting, and bending. FPCs tend to suffer defects of varying copper wire widths, notches, and burrs due to different materials and etching time, and chemical solutions when going through the process. Aiming at short-circuit or open circuit, precision resistance of copper wires and capacitance impedance between wires, the 9331 goes live for testing by just connecting to a manual/pneumatic compact press thimble jig. It not only enables board makers to run 4-wire precision measurement with speed and accuracy, but also cuts PCB O/S test machine investment with less workshop space demand.
- Multi-channel auto test for up to 8 coils at a time
- Optional LCR function (frequency 200KHz)
- High voltage non-destructive pulse pressure measurement technology
- The best WPC/NFC coil quality test station
- AC 3000V, DC 3000V, IR 1000V
- Detect micro-short circuit in between loops within coils by high voltage test
- Analyze PCB coil insulation, inductance, and parallel connection capacitance change by waveform matching
- Optional coil impedance characteristic test item (L for inductance and DCR for DC resistance)
Specifications
Model | 9331 |
Test Pin | 128/256 |
Conductance Test (4-Wire) |
1mΩ~50Ω 1%±1mΩ |
Test Frequency | 1KHz |
AC Test level | 1V |
Resistance Test | 0.1Ω ~ 1 0MΩ 1%±0.1Ω |
Capacitor Test | 10pF~1000µF 1%±10pF |
Inductor Test | - |
Diode Test | 0 - 7V |
Open/Short Test | 1KΩ ~ 50KΩ |
Insulation Test voltage DCHV | 0~ 1500V |
Insulation Test | 0.1MΩ~1.2GΩ ±10% |
Leakage Test voltage ACHV | 0 ~ 1000V |
Leakage Current Test IL | 0.1mA ~5mA |
Conductance Test Time | 100 Points/Sec Approx. |
O/S Test Time | 1,000 Points/Sec |
Input | 1. Auto Learn 2. File Download |
Computer |
option |
Display | option |
Power Supply | AC110/ 220V 500W |
Working Temperature | 10°C~40°C |
Working Humidity | Less than 50% Relative |
Air Supply | 5~8Kg/cm² |
Test Area W*D | 300 x 200 mm |
Cylinder Distance | 250mm |
Cylinder Diameter | Ø 12mm |
Size L*W*H | 750 x 750x 700 mm |
Weight | 120 Kg |