FX-000C19 DIP Test Fixture
  • Terminal Connector:4-Terminal Pair, BNC
  • DUT Connection:4-Terminal
  • Dimensions (approx.):96x34x49mm (W/H/D)
  • Weight (approx.): 170g
  • Applicable Models: 6363~6367、6632、6630
  • Frequency:DC to 50 MHz
  • Max. Voltage: ±42 V peak max. (AC+DC)
  • Operating Temperature: 0°C to 55°C
  • DUT Size:Max.4mm
Inquiry
DC Bias Current Source
6210 (10A)
  • Up to 1MHz
  • Each individual unit can output DC Bias Current 10A (Max.60A)
  • Control by the LCR Meter or Impedance Analyzer
Inquiry
6365 LCR Meter
  •  Test Frequency 10Hz-200kHz
  • Output Impedance 100Ω
  • Open Circuit/Short Circuit
  • Meter Mode
  • List Mode
  • 7.0" TFT, 800×480 color screen
  • Four Parameters Displayed Simultaneously
  • Comparator/BIN
  • Basic Accuracy ±0.05%
  • Using  Graphical Analysis by PC Link
  • RS-232、Handler、LAN、USB Host 、Handler、GPIB
Inquiry
FX-0000C9 Test Fixture
  • Terminal Connector:4-Terminal Pair, BNC
  • DUT Connection:2-Terminal
  • Dimensions (approx.):115x135x126mm (W/H/D)
  • Weight (approx.): 651g
  • Applicable Models: 6632、6630
  • Frequency:DC to 30 MHz
  • Max. Voltage: ±42 V peak max. (AC+DC)
  • Operating Temperature: 0°C to 55°C
  • DUT Size:≤10mm
Inquiry
6240+6632 DC Bias Current Test System
  •  Current and frequency graphic scanning analysis
  • Frequency response 100Hz-3MHz 
  • DC Bias Current Max.320A (6240)
  • DCR Measurement function
  • Built-in the Permeability-μr
  • Long-term consecutive maximum power output
  • Direct Handler interfaces control through Impedance Analyzer
  • Support meter mode and list mode, sweep mode
Inquiry
6364 LCR Meter
  •  Test Frequency 10Hz-100kHz
  • Output Impedance 100Ω
  • Open Circuit/Short Circuit
  • Meter Mode
  • List Mode
  • 7.0" TFT, 800×480 color screen
  • Four Parameters Displayed Simultaneously
  • Comparator/BIN
  • Basic Accuracy ±0.05%
  • Using  Graphical Analysis by PC Link
  • RS-232、Handler、LAN、USB Host 、Handler、GPIB
Inquiry
FX-000C10 Bottom Electrode SMD Test Fixture
  • Terminal Connector:4-Terminal Pair, BNC
  • DUT Connection:2-Terminal
  • Dimensions (approx.):91x80x98mm (W/H/D)
  • Weight (approx.): 237g
  • Applicable Models: 6363~6367、6632、6630
  • Frequency:DC to 30 MHz
  • Max. Voltage: ±42 V peak max. (AC+DC)
  • Operating Temperature: 0°C to 55°C
  • DUT Size:≤9x9x5mm (W/H/D)
Inquiry
6220+6632 DC Bias Current Test System
  •  Current and frequency graphic scanning analysis
  • Frequency response 100Hz-3MHz 
  • DC Bias Current Max.120A (6220)
  • DCR Measurement function
  • Built-in the Permeability-μr
  • Long-term consecutive maximum power output
  • Direct Handler interfaces control through Impedance Analyzer
  • Support meter mode and list mode, sweep mode
Inquiry
6363 LCR Meter
  •  Test Frequency 10Hz-20kHz
  • Output Impedance 100Ω
  • Open Circuit/Short Circuit
  • Meter Mode
  • List Mode
  • 7.0" TFT, 800×480 color screen
  • Four Parameters Displayed Simultaneously
  • Comparator/BIN
  • Basic Accuracy ±0.05%
  • Using  Graphical Analysis by PC Link
  • RS-232、Handler、LAN、USB Host 、Handler、GPIB