FX-000C11 SMD Tweezers Test Leads
  • Terminal Connector:4-Terminal Pair, BNC
  • DUT Connection:4-Terminal
  • Weight (approx.):1m (RG178)
  • Weight (approx.): 170g
  • Applicable Models: 6363~6367、6632、6630
  • Frequency:DC to 10 MHz
  • Max. Voltage: ±42 V peak max. (AC+DC)
  • Operating Temperature: 0°C to 55°C
  • DUT Size:≤10mm
Inquiry
6210+6632 DC Bias Current Test System
  •  Current and frequency graphic scanning analysis
  • Frequency response 100Hz-3MHz 
  • DC Bias Current Max.60A (6210)
  • DCR Measurement function
  • Built-in the Permeability-μr
  • Long-term consecutive maximum power output
  • Direct Handler interfaces control through Impedance Analyzer
  • Support meter mode and list mode, sweep mode
Inquiry
6223+6632 DC Bias Current Test System
  •  Current and frequency graphic scanning analysis
  • Frequency response 100Hz-10MHz 
  • DC Bias Current Max.120A (6223)
  • DCR Measurement function
  • Built-in the Permeability-μr
  • Long-term consecutive maximum power output
  • Direct Handler interfaces control through Impedance Analyzer
  • Support meter mode and list mode, sweep mode
Inquiry
FX-000C12 SMD Test Fixture
  • Terminal Connector:4-Terminal Pair, BNC
  • DUT Connection:2-Terminal
  • Dimensions (approx.):91x42x57mm (W/H/D)
  • Weight (approx.): 148g
  • Applicable Models: 6363~6367、6632、6630
  • Frequency:DC to 30 MHz
  • Max. Voltage: ±42 V peak max. (AC+DC)
  • Operating Temperature: 0°C to 55°C
  • DUT Size:≤7mm
Inquiry
6355/6356+6223/6243 DC Bias Current Test System
  • Frequency Response 100Hz-500kHz (6356)
  • Supports maximum output DC bias current of 320A/120A
  • DCR measurement function
  • Can sustain maximum power output for long periods of time
  • Output impedance: 100Ω
  • Open/short circuit calibration function
  • Supports meter measurement mode/multi-step list testing
Inquiry
6220+6632 DC Bias Current Test System
  •  Current and frequency graphic scanning analysis
  • Frequency response 100Hz-3MHz 
  • DC Bias Current Max.120A (6220)
  • DCR Measurement function
  • Built-in the Permeability-μr
  • Long-term consecutive maximum power output
  • Direct Handler interfaces control through Impedance Analyzer
  • Support meter mode and list mode, sweep mode
Inquiry
F663001 A/B/C BNC Test Leads
  • Terminal Connector:4-Terminal Pair, BNC
  • DUT Connection:4-Terminal
  • Cable Length(approx.):0.5m/1m/2m (A/B/C, RG174)
  • Weight (approx.): 152g
  • Applicable Models: 6363~6367、6632、6630
  • Frequency:DC to 20MHz/10MHz/5MHz (A/B/C)
  • Max. Voltage:±200V peak max.(AC+DC)
  • Operating Temperature: 0°C to 55°C
Inquiry
6210+6632 DC Bias Current Test System
  •  Current and frequency graphic scanning analysis
  • Frequency response 100Hz-3MHz 
  • DC Bias Current Max.60A (6210)
  • DCR Measurement function
  • Built-in the Permeability-μr
  • Long-term consecutive maximum power output
  • Direct Handler interfaces control through Impedance Analyzer
  • Support meter mode and list mode, sweep mode
Inquiry
FX-0000C7 Dielectric Material Test Fixture
  • Terminal Connector:4-Terminal Pair, BNC
  • DUT Connection:2-Terminal
  • Dimensions (approx.):115x155x126mm (W/H/D)
  • Weight (approx.): 827g
  • Applicable Models: 6632、6630
  • Frequency:≤30MHz
  • Max. Voltage: ±42 V peak max. (AC+DC)
  • Operating Temperature: 0°C to 55°C
  • DUT Size:≤10mm
  • Electrode Diameter:38mm (Type A),5mm(Type B)
Inquiry