The 6630 precision LCR meter provide seven frequency options (10 Hz to 1/3/5/10/20/30/50MHz), it is suitable for the LCR testes of AC signals. The measurement in a continuously changing environment can be executed stage-by-stage with the test frequency and grade, and high-speed continuous tests can be performed under different test and mode conditions. The 6630 has output impedance 25Ω/100Ω can be switched, Auto Level control(ALC) , List mode function. Comparator function and Handler BIN classification function for component good and defective product classification. It supports RS-232、GPIB、Handler、LAN、USB Host/Device.
The 6630 also supports a variety of fixtures, such as liquid dielectric material test fixture, dielectric material test fixture and magnetic material test fixture.
- Signal source frequency range: 10 Hz to 1/3/5/10/20/30/50 MHz
- Basic accuracy up to ±0.05%
- ALC function
- Output impedance 25Ω/100Ω, switchable
- Support meter mode and list mode, can used with various fixtures, such as: liquid dielectric material test fixture, dielectric material test fixture and magnetic material test fixture
- Ultra-high measuring speed < 3ms
- Open circuit/short circuit/load calibration function
- Up to four component parameters can be selected in the electric meter mode. The induction and DCR values can be measured and displayed simultaneously
- Auto component classification: Comparator function and Handler BIN classification function
- Support RS-232、GPIB、Handler、LAN、USB Host/Device interfaces
- PC connection data analysis software is available
![]() |
![]() |
|
Four Parameters Displayed Simultaneously 7.0”TFT, 800x480 color screen, and four parameters can displayed simultaneously. |
Correction Before measuring the DUT, you should select "Correction" button to do open, short, and HF Load or SPOT Load correction. |
|
![]() |
![]() |
|
Measure Inductor (DCR) Inductor coil turns and winding materials will affect DCR value. The key parameters for inductor are Ls / Lp / Q / SRF / DCR. |
List Mode 50 groups of list mode setting (Each group contains up to 15 steps).
|
|
|
|
|
Output Impedance 25Ω/100Ω and Auto Level Control (ALC)
|
Dielectric Material Test Fixture (FX-0000C7) Using the dielectric material test fixture for measuring PCB board or ceramic board. 6630 built-in formula to directly calculate the material dielectric value εr ', εr ".
|
|
![]() |
![]() |
|
Liquid Dielectric Material Test Fixture (FX-000C20) Using the liquid dielectric material test fixture for measuring the characteristics of electrochemical materials.
|
Magnetic Material Test Fixture (FX-0000C8) Using the magnetic material test fixture for measuring of permeability of various toroidal cores or ferrite cores and electromagnetic shielding coating materials, 6630 built-in formula to directly calculate the permeability coefficient value μr'、μr"". |
|
![]() |
||
Automatic Production Line Connect 6630 RS-232, LAN, GPIB or Handler to automatic machine (measuring speed<3mS),automated production is the most efficiency. |
|
Specification
Test Frequency |
6630-1 | 10Hz ~ 1MHz |
6630-3 | 10Hz ~ 3MHz | |
6630-5 | 10Hz ~ 5MHz | |
6630-10 | 10Hz ~ 10MHz | |
6630-20 | 10Hz ~ 20MHz | |
6630-30 | 10Hz ~ 30MHz | |
6630-50 | 10Hz ~ 50MHz | |
Minimum Resolution | 100mHz, 6-bit Frequency Input |
|
Accuracy |
7 ppm±100mHz |
|
Basic Accuracy | ± 0.05% | |
AC Drive Level |
Test Signal Voltage Level | 10mV - 2Vrms(Ro 100Ω) 10mV - 1Vrms(Ro 25Ω) |
Voltage Minimum Resolution | 1mV | |
Accuracy | ALC ON:6% * Voltage ± 2mV ALC OFF:10% * Voltage ± 2mV |
|
Test Signal Current Level | 200µA - 20mArms | |
Current Minimum Resolution |
10µA | |
Accuracy | ALC ON:6% * Current ± 20µA ALC OFF:10% * Current ± 20µA |
|
DC Drive Level | 1V (fixed) | |
Test Time (The fastest) | < 3ms | |
Output Impedance |
25Ω/100Ω, switchable (Nominal value) |
|
Parameters | |Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C、 Vdc-Idc、ESR、ε' ε"and μr' μr" | |
Measurement Mode |
Meter mode, list mode |
|
Measurement Circuit |
Series/Parallel |
|
Correction |
Open Circuit/ Short Circuit/Load correction | |
List mode | 50 groups of Multi-steps setting (Each group contains up to 15 steps) | |
BIN | 9 | |
Comparator | ABS、ΔABS、Δ%、OFF | |
Bulit-in Storge |
100 sets LCR Meter setting documents, 50 sets list mode setting documents |
|
USB Host Storge | LCR setting documents, list mode setting documents, BMP graphics | |
Interface | RS-232、GPIB、Handler、LAN、USB Host/Device | |
Power Supply | Voltage | 90V ~ 264Vac |
Frequency | 47Hz ~ 63Hz | |
Power Consumption |
Low power consumption: Maximum 30W (Nominal value) |
|
Display |
7.0”TFT, 800x480 color screen |
|
Environment |
Temperature: 10℃ ~ 40℃ Humidity: ≦80% |
|
Dimension (W*H*D) | 336x147x340 mm | |
Weight | 3 kg |
Parameters Measurement Ranges
|Z| | 0.000 mΩ - 9999.99 MΩ |
R, X | ± 0.000 mΩ - 9999.99 MΩ |
|Y| | 0.00000 uS - 999.999 kS |
G, B | ± 0.00000 uS - 999.999 kS |
θRAD | ± 0.00000 - 3.14159 |
θDEG | ± 0.000° - 180.000° |
Cs, Cp | ± 0.00000 pF - 9999.99 F |
Ls, Lp | ± 0.00 nH - 9999.99 kH |
D | 0.00000 - 9999.99 |
Q | 0.00 - 9999.99 |
Δ | ± 0.00% - 9999.99% |
Rdc | 0.00 mΩ - 99.9999 MΩ |
εr' εr'' | 0 - 100000 |
μr' μr'" | 0 - 100000 |
Applications
Passive Components |
Capacitor, Inductor, Resistor, Transformer, Ceramic resonator, Quartz Crystal |
Semiconductor Components |
The CV characteristics analysis of varactor diodes, Diodes |
Dielectric Material |
Estimation on permittivity and consumption tangent of plastic, ceramic and PCB |
Other Components |
Estimation of the impedance of PCB components |
Standard Accessories
- Power Cord
- User Manual(CD)
- Test Fixture (FX-000C19)
Optional Accessories
- PC Link software
- Kelvin Clip Leads with BNC Box (F423906A)
- DIP Test Fixture(F423503)
- DIP Test Fixture(F423504)
- Test Fixture (FX-0000C6)
- SMD Test Fixture(F423905)
- Bottom Electrode SMD Test Fixture (FX-000C10)
- SMD Tweezers Test Leads (FX-000C11)
- SMD Test Fixture(FX-000C12)
- Dielectric Material Test Fixture (FX-0000C7)
- Magnetic Material Test Fixture (FX-0000C8)
- Test Fixture (FX-0000C9)
- Liquid Dielectric Material Test Fixture(FX-000C20)
- BNC Test Leads (F663001A/B/C)
- ±200Vdc External Voltage Bias(F420001)
- ±40Vdc External Voltage Bias(F420003)