Search
6630
Component Tester
LCR Meter 10Hz~1/3/5/10/20/30MHz

The 6630 precision LCR meter provide six frequency options (10 Hz to 1/3/5/10/20/30MHz), it is suitable for the LCR testes of AC signals. The measurement in a continuously changing environment can be executed stage-by-stage with the test frequency and grade, and high-speed continuous tests can be performed under different test and mode conditions. The 6630 has output impedance 25Ω/100Ω can be switched, Auto Level control(ALC) , List mode function. Comparator function and Handler BIN classification function for component good and defective product classification. It supports RS-232、GPIB、Handler、LAN、USB Host/Device.

The 6630 also supports a variety of fixtures, such as liquid dielectric material test fixture, dielectric material test fixture and magnetic material test fixture.

  • Signal source frequency range: 10 Hz to 1/3/5/10/20/30 MHz
  • Basic accuracy up to ±0.05%
  • ALC function
  • Output impedance 25Ω/100Ω, switchable
  • Support meter mode and list mode, can used with various fixtures, such as: liquid dielectric material test fixture, dielectric material test fixture and magnetic material test fixture
  • Ultra-high measuring speed < 3ms
  • Open circuit/short circuit/load calibration function
  • Up to four component parameters can be selected in the electric meter mode. The induction and DCR values can be measured and displayed simultaneously
  • Auto component classification: Comparator function and Handler BIN classification function
  • Support RS-232、GPIB、Handler、LAN、USB Host/Device interfaces
  • PC connection data analysis software is available
     
 
Four Parameters Displayed Simultaneously   
7.0”TFT, 800x480 color screen, and four parameters can displayed simultaneously.
  Correction
Before measuring the DUT, you should select "Correction" button to do open, short, and HF Load or SPOT Load correction.
     
   

Measure Inductor (DCR) 

Inductor coil turns and winding materials will affect DCR value. The key parameters for inductor are Ls / Lp / Q / SRF / DCR.

 

List Mode

50 groups of list mode setting (Each group contains up to 15 steps).

 

     

 

Output Impedance 25Ω/100Ω and Auto Level Control (ALC)

 

 

 

 

 

 

Dielectric Material Test Fixture (FX-0000C7)

Using the dielectric material test fixture for measuring PCB board or ceramic board. 6630 built-in formula to directly calculate the material dielectric value εr ', εr ".

 

 

     
   

Liquid Dielectric Material Test Fixture (FX-000C20)

Using the liquid dielectric material test fixture for measuring the characteristics of electrochemical materials.

 

 

 

Magnetic Material Test Fixture (FX-0000C8)

Using the magnetic material test fixture for measuring of permeability of various toroidal cores or ferrite cores and electromagnetic shielding coating materials, 6630 built-in formula to directly calculate the permeability coefficient value μr'、μr"".

     
   

Automatic Production Line

Connect 6630 RS-232, LAN, GPIB or Handler to automatic machine (measuring speed<3mS),automated production is the most efficiency.

   

 

 

 Specification

   

 

     

 Test Frequency 

6630-1 10Hz ~ 1MHz
6630-3 10Hz ~ 3MHz
6630-5 10Hz ~ 5MHz
6630-10 10Hz ~ 10MHz
6630-20 10Hz ~ 20MHz
6630-30 10Hz ~ 30MHz
Minimum Resolution 100mHz, 6-bit Frequency Input
Accuracy

7 ppm±100mHz

Basic Accuracy ± 0.05% 

 

 

 

AC Drive Level    

Test Signal Voltage Level  10mV - 2Vrms
Voltage Minimum Resolution 1mV
Accuracy ALC ON:6% Voltage ± 2mV
ALC OFF
:10% Voltage ± 2mV
Test Signal Current Level 200µA - 20mArms

Current Minimum Resolution

10µA
Accuracy ALC ON:6% Current ± 20µA
ALC OFF
:10% Current ± 20µA
DC Drive Level     1V (fixed)
Test Time  (The fastest) < 3ms
Output Impedance

25Ω/100Ω, switchable (Nominal value)

Parameters |Z||Y|、θ、XRGBLDQDCRC、 Vdc-IdcESR、ε' ε"and μr' μr"
Measurement Mode

Meter mode, list mode

Measurement Circuit 

Series/Parallel

Correction

Open Circuit/ Short Circuit/Load correction
List mode 50 groups of Multi-steps setting (Each group contains up to 15 steps)
BIN 9
Comparator  ABS、ΔABS、Δ%、OFF
Bulit-in Storge

100 sets LCR Meter setting documents, 50 sets list mode setting documents

USB Host Storge LCR setting documents, list mode setting documents, BMP graphics
Interface RS-232、GPIB、Handler、LAN、USB Host/Device
Power Supply  Voltage 90V  264Vac
Frequency 47Hz ~ 63Hz

Power Consumption

Low power consumption: Maximum 30W (Nominal value)

Display

7.0”TFT, 800x480 color screen

Environment

Temperature: 10℃ ~ 40℃   Humidity: ≦80%

Dimension (W*H*D) 336x147x340 mm
Weight  3 kg

Parameters Measurement Ranges

  
|Z| 0.000 mΩ - 9999.99 MΩ
R, X ± 0.000 mΩ - 9999.99 MΩ
|Y| 0.00000 uS - 999.999 kS
G, B ± 0.00000 uS - 999.999 kS
θRAD ± 0.00000 - 3.14159
θDEG ± 0.000° - 180.000°
Cs, Cp ± 0.00000 pF - 9999.99 F
Ls, Lp ± 0.00 nH - 9999.99 kH
D 0.00000 - 9999.99
Q 0.00 - 9999.99
Δ ± 0.00% - 9999.99%
Rdc 0.00 mΩ - 99.9999 MΩ
εr' εr'' 0 - 100000
μr' μr'"  0 - 100000

Applications

  

Passive Components

Capacitor, Inductor, Resistor, Transformer, Ceramic resonator, Quartz Crystal

Semiconductor Components

The CV characteristics analysis of varactor diodes, Diodes

Dielectric Material

Estimation on permittivity and consumption tangent of plastic, ceramic and PCB

Other Components

Estimation of the impedance of PCB components
Datasheet
Video

影片名稱:

益和 MICROTEST 
LCR 測試儀6630 高速檢測SMD電感搭載自動化產線測包機

 

For YOUKU Link:

1. 益和 MICROTEST LCR 測試儀6630 高速檢測SMD電感搭載自動化產線測包機

影片名稱:

益和 MICROTEST 
LCR 測試儀 6630 搭配自動化測包機

LCR Meter 6630 with automatic testing and packing machine for
electronic components

 

For YOUKU Link:

1. 益和 MICROTEST LCR 測試儀 6630 搭配自動化測包機

Accessories/Fixtures

Standard Accessories

  • Power Cord
  • User Manual(CD)
  • Test Fixture (FX-000C19)

Optional Accessories

  • PC Link software
  • Kelvin Clip Leads with BNC Box (F423906A)
  • DIP Test Fixture(F423503)
  • DIP Test Fixture(F423504)
  • Test Fixture (FX-0000C6)
  • SMD Test Fixture(F423905)
  • Bottom Electrode SMD Test Fixture (FX-000C10)
  • SMD Tweezers Test Leads (FX-000C11)
  • SMD Test Fixture(FX-000C12)
  • Dielectric Material Test Fixture (FX-0000C7)
  • Magnetic Material Test Fixture (FX-0000C8)
  • Test Fixture (FX-0000C9)
  • Liquid Dielectric Material Test Fixture(FX-000C20)
  • BNC Test Leads (F663001A/B/C)
  • ±200Vdc External Voltage Bias(F420001)
  • ±40Vdc External Voltage Bias(F420003)
TOPTOP