Search
6632
Component Tester
Impedance Analyzer 10Hz~1/3/5/10/20/30MHz
The 6632 precision impedance analyzer has six frequency options(10 Hz to 1/3/5/10/20/30MHz). The equivalent circuit analysis function supports 7 different parameter models (three-element, four-element), it can help customers model the impedance versus frequency characteristics. 6632 Built-in DC Bias voltage ±12V, optional plug-in DC Bias voltage/current 0 to ±40V/±100mA. It can measurement of piezoelectric element admittance circle, and can measure DC bias characteristic of capacitance value. 6632 can use with DC bias current test system 6210, 6220, or 6240. Support RS-232、GPIB、Handler、LAN、USB Host/Device interfaces, PC connection software capabilities to improve the design and test efficiency significantly.

The 6632 supports a variety of accessories that meet customer’s need. Such as dielectric material test fixture that allows PCB designed engineers to reduce the faulty conditions with the comprehensive information of permittivity while designing PCB layouts, liquid dielectric material test fixture for measuring dielectric constant of pure water and air, magnetic material test fixture for measuring of permeability of various toroidal cores or ferrite cores and electromagnetic shielding coating materials……etc.
  • Signal source frequency range: 10 Hz to 1/3/5/10/20/30 MHz
  • Basic accuracy up to ±0.08% (typical ±0.05%)
  • ALC function
  • Output impedance 25Ω/100Ω, switchable
  • Support meter mode and list mode, sweep mode, and equivalent circuit analysis(option) function
  • Built-in DC Bias voltage ±12V, optional plug-in DC Bias voltage/current 0 to ±40V/±100mA
  • Measurement of piezoelectric element admittance circle, and can measure DC bias characteristic of capacitance value.
  • Ultra-high measuring speed < 3ms
  • Open circuit/short circuit/load correct function
  • Up to four component parameters can be selected in the electric meter mode. The induction and DCR values can be measured and displayed simultaneously
  • Auto component classification: Comparator function and Handler BIN classification function
  • Can be used with various fixtures, such as: liquid dielectric material test fixture, dielectric material test fixture and magnetic material test fixture….etc.
  • Using with DC bias current test system 6210/6220/6240
  • Support RS-232、GPIB、Handler、LAN、USB Host/Device interfaces
  • PC connection data analysis software is available
     
 
Four Parameters Displayed Simultaneously   
7.0”TFT, 800x480 color screen, and four parameters can displayed simultaneously.
  Correction
Before measuring the DUT, you should select "Correction" button to do open, short, and HF Load or SPOT Load correction.
     
   

Measure Inductor (DCR)

Inductor coil turns and winding materials will affect DCR value. The key parameters for inductor are Ls / Lp / Q / SRF / DCR.

 

List Mode

50 groups of list mode setting (Each group contains up to 15 steps).

 

     

 

Output Impedance 25Ω/100Ω and Auto Level Control (ALC)








 

 

 

Dielectric Material Test Fixture (FX-0000C7)/Liquid Dielectric Material Test Fixture (FX-000C20)

Using the dielectric material test fixture for measuring PCB board or ceramic board. 6632 built-in formula to directly calculate the material dielectric value εr ', εr ".Using the liquid dielectric material test fixture for measuring the characteristics of electrochemical materials.

 

     
     

Magnetic Material Test Fixture (FX-0000C8)

Using the magnetic material test fixture for measuring of permeability of various toroidal cores or ferrite cores and electromagnetic shielding coating materials, 6632 built-in formula to directly calculate the permeability coefficient value μr'、μr"".

 

 

 

Evaluation of DC bias voltage characteristics with semiconductor wafer or ceramic multilayer capacitors

 

 

 

 

 

 

     
     

Equivalent Circuit Analysis(Option)

Model E is suitable for measuring and analyzing the resonators, piezoelectric element or transducer. The two-resonance frequency characteristic diagram presented above is suited for Model E.

  It has seven different models, combine with different types of parameters ( R, L, C) help customers model the impedance versus frequency characteristics and self-resonant frequency (SRF).
     
   

Testing PC board  inductance coil

 

 

 

 

 

 

Evaluation impedance characteristics of RFID / NFC  automotive wireless of antennas 

 

 

 

 

 

     

Piezoelectric element/quartz crystal analysis frequency characteristics

 

   

 

 Specification

   

 

     

 

 

Test Frequency 

6332-1/1S 10Hz ~ 1MHz
6332-3/3S 10Hz ~ 3MHz
6332-5/5S 10Hz ~ 5MHz
6332-10/10S 10Hz ~ 10MHz
6332-20/20S 10Hz ~ 20MHz
6632-30/30S 10Hz ~ 30MHz
* Optional Equivalent Circuit Analysis function (S model)
Minimum Resolution 100mHz, 6-bit Frequency Input
Accuracy

7 ppm±100mHz

Basic Accuracy ± 0.08%  (typical ±0.05%)

 

 

 

AC Test Signal Level   

Test Signal Voltage Level  10mV - 2Vrms
Voltage Minimum Resolution 1mV
Accuracy ALC ON:6% Voltage ± 2mV
ALC OFF
:10% Voltage ± 2mV
Test Signal Current Level 200µA - 20mArms

Current Minimum Resolution

10µA
Accuracy ALC ON:6% Current ± 20µA
ALC OFF
:10% Current ± 20µA
DC Test Signal Level    1V (Fixed)
Test Time  (The fastest) < 3mS
Output Impedance

25Ω/100Ω, switchable (Nominal value)

Parameters |Z||Y|、θ、XRGBLDQDCRC、 Vdc-IdcESR、ε and μr
Bias Can be using with DC Bias 6210/6220/6240
Measurement Mode

Meter mode, list mode, sweep mode, and optional equivalent circuit analysis function(S model)

Correction

Open Circuit/ Short Circuit/Load Correction
Measurement Circuit   Series/Parallel
List mode 50 groups of list mode setting (Each group contains up to 15 steps)
Equivalent Circuit Analysis Three elements、Four elements (option) 
DC bias voltage -12 to +12V, 0.3% ±1.5mV, 100Hz to 30MHz
BIN 9 Level
Comparator ABS、ΔABS、Δ%、OFF
Internal Storage

100 sets LCR setting documents, 50 groups of list mode setting 

USB Storage LCR setting documents, list mode setting document, BMP graphics, Sweep screen and test result data

Interface  

RS-232、GPIB、Handler、LAN、USB Host/Device
Option   PC connection software
Equivalent Circuit Analysis
plug-in DC Bias voltage/current 0 to ±40V/±100mA
Power Supply   Voltage 90V  264Vac
Frequency  47Hz ~ 63Hz
Power Consumption Low power consumption: Maximum 30W (Nominal value)
Display 7.0”TFT, 800x480 color screen
Environment Temperature: 10℃ ~ 40℃   Humidity: ≦90%
Dimension (W*H*D) 336x147x340 mm
Weight  3.95Kg

Parameters Measurement Ranges

  
|Z| 0.000 mΩ to 9999.99 MΩ
R, X ± 0.000 mΩ to 9999.99 MΩ
|Y| 0.00000 μS to 999.999 kS
G, B ± 0.00000 μS to 999.999 kS
θRAD ± 0.00000 to 3.14159
θDEG ± 0.000° to 180.000°
Cs, Cp ± 0.00000 pF to 9999.99 F
Ls, Lp ± 0.00 nH to 9999.99 kH
D 0.00000 to 9999.99
Q 0.00 to 9999.99
Δ ± 0.00% to 9999.99%
Rdc 0.00 mΩ to 99.9999 MΩ
εr' εr'' 0 to 10000
μr' μr'' 0 to 10000

Applications

  

Passive Components

Capacitor, Inductor, Resistor, Transformer, Ceramic resonator, Quartz Crystal

Semiconductor Components

The CV characteristics analysis of varactor diodes, Diodes

Dielectric Material

Estimation on permittivity and consumption tangent of plastic, ceramic and PCB

Electromagnetic Material  
Other Components Estimation of the impedance of PCB components
Datasheet
Video

 

影片名稱:

益和 MICROTEST

Impedance analyzer 6632 highlights 特色介紹 

 

For YOUKU Link:
1. Impedance analyzer 6632 highlights 特色介紹

影片名稱:

益和 MICROTEST

Impedance analyzer 6632&LCR Meter 6630
Correction 校正操作說明

 

For YOUKU Link:
1. Impedance analyzer 6632&LCR Meter 6630 Correction 校正操作說明

Accessories/Fixtures

Standard Accessories

  • Power Cord
  • User Manual(CD)
  • F423902Test Fixture (FX-000C19)

Optional Accessories

  • Kelvin Clip Leads with BNC Box (F423906A)
  • DIP Test Fixture(F423503)
  • DIP Test Fixture(F423504)
  • Test Fixture (FX-0000C6)
  • SMD Test Fixture(F423905)
  • Bottom Electrode SMD Test Fixture (FX-000C10)
  • SMD Tweezers Test Leads (FX-000C11)
  • SMD Test Fixture(FX-000C12)
  • Dielectric Material Test Fixture (FX-0000C7)
  • Magnetic Material Test Fixture (FX-0000C8)
  • Test Fixture (FX-0000C9)
  • Liquid Dielectric Material Test Fixture(FX-000C20)
  • BNC Test Leads (F663001A/B/C)
  • ±200Vdc External Voltage Bias(F420001)
  • ±40Vdc External Voltage Bias(F420003)
TOPTOP